{"id":7505678860441,"title":"Cole-Parmer Nylon Membrane Filters; 0.2µm Pore, 47mm Dia, 100\/Pk","handle":"cole-parmer-nylon-membrane-filters-0-2µm-pore-47mm-dia-100-pk","description":"\u003ch3\u003eCole-Parmer Nylon Membrane Filters; 0.2µm Pore, 47mm Dia, 100\/Pk\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eProcess for Selecting a Filter 1. Determine the particle\nsize to be retained or filtered. Membranes will retain all particles equal to,\nand larger than their designated pore size. 2. Assess the chemical\ncompatibility of the membrane filter with the liquid or gas to be filtered.\nConsider the chemical resistance properties of all the parts that will contact\nthe filtrate. 3. Depending on the procedure performed, the membrane color or\nsurface pattern may be important. 4. Also consider hydrophilic or hydrophobic\nmembranes, temperature, flow rate, throughput, and sterilization needs Read\nmore Types of Membrane Materials Cellulose Nitrate and Cellulose Acetate\nCellulose Nitrate (CN) membrane is the most popular membrane used in\nanalytical and laboratory filtration. CN membrane has excellent wetting\nproperties and gives fastest flow rates with aqueous solutions. Cellulose\nAcetate membrane is a mixture of cellulose triacetate and diacetate that\ncreates a strong membrane in both lateral and longitudinal directions. In\naddition, the membrane has a low static charge, a very low aqueous\nextractability, and good solvent resistance to low molecular weight alcohols.\nMixed Cellulose Ester Mixed Cellulose Ester membrane provides a more uniform\nand smoother surface compared to pure nitrocellulose membrane. This membrane\nis typically used to count or analyze particles contained in liquids or\ncaptured from aerosols. Nylon Nylon membrane is strong, inherently\nhydrophilic, and compatible with a broad range of aqueous solutions including\nalcohols and solvents used in HPLC work. Polyethersulfone (PES) and PTFE\nPolyethersulfone (PES) membrane is hydrophilic and low protein binding. No\nexternal wetting agents are required, resulting in low extractables. PES\nmembrane generally offers fast flow rate and better chemical resistance than\ncellulose acetate membranes. PTFE membrane is strong, highly porous, and inert\nto most chemically aggressive solvents, strong acids, and bases. Chemical and\nthermal limitations are imposed by the backing material. Read more\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003eManufactured by Cole-Parmer\u003c\/li\u003e\n \u003cli\u003eCountry of origin - India\u003c\/li\u003e\n \u003cli\u003eProduct - Nylon membrane filter\u003c\/li\u003e\n \u003cli\u003ePackage Dimensions: 2.5\" L x 2.5\" W x 1.75\" H\u003c\/li\u003e\n \u003c\/ul\u003e\n\u003chr class=\"py-vbody\" style=\"display: none\"\u003e\n\n\n","published_at":"2022-08-31T05:04:50+10:00","created_at":"2022-08-31T05:04:51+10:00","vendor":"Cole-Parmer","type":"Filter Membrane","tags":["industrial2"],"price":23300,"price_min":23300,"price_max":23300,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":42549609201817,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"B01M03001I","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Cole-Parmer Nylon Membrane Filters; 0.2µm Pore, 47mm Dia, 100\/Pk","public_title":null,"options":["Default Title"],"price":23300,"weight":91,"compare_at_price":null,"inventory_management":null,"barcode":"AO-15945-26","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/soundstores.net\/cdn\/shop\/products\/B01M03001I.jpg?v=1661963161"],"featured_image":"\/\/soundstores.net\/cdn\/shop\/products\/B01M03001I.jpg?v=1661963161","options":["Title"],"media":[{"alt":null,"id":27718086197401,"position":1,"preview_image":{"aspect_ratio":1.0,"height":346,"width":346,"src":"\/\/soundstores.net\/cdn\/shop\/products\/B01M03001I.jpg?v=1661963161"},"aspect_ratio":1.0,"height":346,"media_type":"image","src":"\/\/soundstores.net\/cdn\/shop\/products\/B01M03001I.jpg?v=1661963161","width":346}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eCole-Parmer Nylon Membrane Filters; 0.2µm Pore, 47mm Dia, 100\/Pk\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eProcess for Selecting a Filter 1. Determine the particle\nsize to be retained or filtered. Membranes will retain all particles equal to,\nand larger than their designated pore size. 2. Assess the chemical\ncompatibility of the membrane filter with the liquid or gas to be filtered.\nConsider the chemical resistance properties of all the parts that will contact\nthe filtrate. 3. Depending on the procedure performed, the membrane color or\nsurface pattern may be important. 4. Also consider hydrophilic or hydrophobic\nmembranes, temperature, flow rate, throughput, and sterilization needs Read\nmore Types of Membrane Materials Cellulose Nitrate and Cellulose Acetate\nCellulose Nitrate (CN) membrane is the most popular membrane used in\nanalytical and laboratory filtration. CN membrane has excellent wetting\nproperties and gives fastest flow rates with aqueous solutions. Cellulose\nAcetate membrane is a mixture of cellulose triacetate and diacetate that\ncreates a strong membrane in both lateral and longitudinal directions. In\naddition, the membrane has a low static charge, a very low aqueous\nextractability, and good solvent resistance to low molecular weight alcohols.\nMixed Cellulose Ester Mixed Cellulose Ester membrane provides a more uniform\nand smoother surface compared to pure nitrocellulose membrane. This membrane\nis typically used to count or analyze particles contained in liquids or\ncaptured from aerosols. Nylon Nylon membrane is strong, inherently\nhydrophilic, and compatible with a broad range of aqueous solutions including\nalcohols and solvents used in HPLC work. Polyethersulfone (PES) and PTFE\nPolyethersulfone (PES) membrane is hydrophilic and low protein binding. No\nexternal wetting agents are required, resulting in low extractables. PES\nmembrane generally offers fast flow rate and better chemical resistance than\ncellulose acetate membranes. PTFE membrane is strong, highly porous, and inert\nto most chemically aggressive solvents, strong acids, and bases. Chemical and\nthermal limitations are imposed by the backing material. Read more\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003eManufactured by Cole-Parmer\u003c\/li\u003e\n \u003cli\u003eCountry of origin - India\u003c\/li\u003e\n \u003cli\u003eProduct - Nylon membrane filter\u003c\/li\u003e\n \u003cli\u003ePackage Dimensions: 2.5\" L x 2.5\" W x 1.75\" H\u003c\/li\u003e\n \u003c\/ul\u003e\n\u003chr class=\"py-vbody\" style=\"display: none\"\u003e\n\n\n"}

Cole-Parmer Nylon Membrane Filters; 0.2µm Pore, 47mm Dia, 100/Pk

In Stock. Leaves warehouse within 2 - 3 business days

$233.00 AUD
Maximum quantity available reached.
Free Shipping Australia Wide
100% Safe & Secure Checkout
100 Days Return Policy *
1 Year Warranty *

Cole-Parmer Nylon Membrane Filters; 0.2µm Pore, 47mm Dia, 100/Pk

Process for Selecting a Filter 1. Determine the particle size to be retained or filtered. Membranes will retain all particles equal to, and larger than their designated pore size. 2. Assess the chemical compatibility of the membrane filter with the liquid or gas to be filtered. Consider the chemical resistance properties of all the parts that will contact the filtrate. 3. Depending on the procedure performed, the membrane color or surface pattern may be important. 4. Also consider hydrophilic or hydrophobic membranes, temperature, flow rate, throughput, and sterilization needs Read more Types of Membrane Materials Cellulose Nitrate and Cellulose Acetate Cellulose Nitrate (CN) membrane is the most popular membrane used in analytical and laboratory filtration. CN membrane has excellent wetting properties and gives fastest flow rates with aqueous solutions. Cellulose Acetate membrane is a mixture of cellulose triacetate and diacetate that creates a strong membrane in both lateral and longitudinal directions. In addition, the membrane has a low static charge, a very low aqueous extractability, and good solvent resistance to low molecular weight alcohols. Mixed Cellulose Ester Mixed Cellulose Ester membrane provides a more uniform and smoother surface compared to pure nitrocellulose membrane. This membrane is typically used to count or analyze particles contained in liquids or captured from aerosols. Nylon Nylon membrane is strong, inherently hydrophilic, and compatible with a broad range of aqueous solutions including alcohols and solvents used in HPLC work. Polyethersulfone (PES) and PTFE Polyethersulfone (PES) membrane is hydrophilic and low protein binding. No external wetting agents are required, resulting in low extractables. PES membrane generally offers fast flow rate and better chemical resistance than cellulose acetate membranes. PTFE membrane is strong, highly porous, and inert to most chemically aggressive solvents, strong acids, and bases. Chemical and thermal limitations are imposed by the backing material. Read more

Product Features

  • Manufactured by Cole-Parmer
  • Country of origin - India
  • Product - Nylon membrane filter
  • Package Dimensions: 2.5" L x 2.5" W x 1.75" H