Shop with us and enjoy complimentary shipping on all orders.

{"id":8530716393625,"title":"Hailege 2pcs 24V 5A AC Current Sensor Current Detection Relay 24V AC Current Relay Module AC Sensor Relay Switch with Overcurrent Protection 24 V","handle":"hailege-2pcs-24v-5a-ac-current-sensor-current-detection-relay-24v-ac-current-relay-module-ac-sensor-relay-switch-with-overcurrent-protection-24-v","description":"\u003ch3\u003eHailege 2pcs 24V 5A AC Current Sensor Current Detection Relay 24V AC Current Relay Module AC Sensor Relay Switch with Overcurrent Protection\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eSpecifications: Operating voltage: DC 5 V \/ 12 V. 24 V. Working current: \u0026lt;20\nmA. Frequency range: 20 Hz - 400 Hz. Output mode: switching signal output.\nHumidity: 0-95% RH. Size: 4.4 x 3.8 cm \/ 1.73 x 1.5 inches. Interfaces: VCC:\nPositive; GND: Negative; NO: Normally open, NO and COM are disconnected before\nthe relay is closed, and short circuit after closing the relay COM: common,\ncommon relay interface; NC: Normally closed, NC and COM are short-circuited\nbefore the relay is closed, and disconnected after the relay is closed\nInstructions: 5A overcurrent protection. The sensor module uses a current\ntransformer to collect the AC signal to reach the overcurrent signal output of\nthe relay within 0-5 A. Relay cable in case of overcurrent, relay disengaged\nwhen there is no overcurrent. Users can use the three relay ports COM, NC, NO\nto turn the external circuit on and off to achieve overcurrent protection. Use\nthe potentiometer to adjust the overcurrent protection point, the right\nadjustment reduces the detection current. 1. Measure the wire through the\ncurrent transformer, connect VCC and GND to the DC12V power supply. 2. Adjust\nthe potentiometer when you hear the sound of the relay train (can be measured\nwith a multimeter COM and NO whether it was on when connected to the activated\nrelay mean), then reduce or interrupt the current flowing through the tested\ncable when the relay releases this overcurrent protection point at that time\n(available for COM and NC measurement of the multimeter. whether it is\nconnected when connected to the relay agent has been solved). Box contents: 2\nx AC current sensor relay modules (5V 12V 24V optional, you will receive the\ntwo same, no mixed types.)\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003eThe resolution of current detection can change the parameters of the resistance parameters\u003c\/li\u003e\n \u003cli\u003e5A AC current sensor current detection sensor\u003c\/li\u003e\n \u003cli\u003eAC relay switch, 5V 12V 24V optional\u003c\/li\u003e\n \u003cli\u003eAdjustment of the critical point of the overcurrent signal, adjustable, the current detection range AC0.3A-5A\u003c\/li\u003e\n \u003cli\u003eWe offer the declaration of conformity. This product also includes an electronic user manual available in English, German, French, Spanish, Italian, Polish and Dutch. If you need support, please contact us.\u003c\/li\u003e\n \u003c\/ul\u003e","published_at":"2025-09-25T00:03:03+10:00","created_at":"2025-09-25T00:02:59+10:00","vendor":"Hailege","type":"Current Sensors","tags":["industryDE_Sep2025"],"price":11600,"price_min":11600,"price_max":11600,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":45743437250713,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"de-B0CJY473TS","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Hailege 2pcs 24V 5A AC Current Sensor Current Detection Relay 24V AC Current Relay Module AC Sensor Relay Switch with Overcurrent Protection 24 V","public_title":null,"options":["Default Title"],"price":11600,"weight":50,"compare_at_price":null,"inventory_management":"shopify","barcode":"H-1-1815-24V","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/soundstores.net\/cdn\/shop\/files\/de-B0CJY473TS.jpg?v=1775749780","\/\/soundstores.net\/cdn\/shop\/files\/51Ov01FNAqL.jpg?v=1758722582","\/\/soundstores.net\/cdn\/shop\/files\/51mrE86xYoL.jpg?v=1758722582"],"featured_image":"\/\/soundstores.net\/cdn\/shop\/files\/de-B0CJY473TS.jpg?v=1775749780","options":["Title"],"media":[{"alt":null,"id":34626781413529,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1122,"width":1122,"src":"\/\/soundstores.net\/cdn\/shop\/files\/de-B0CJY473TS.jpg?v=1775749780"},"aspect_ratio":1.0,"height":1122,"media_type":"image","src":"\/\/soundstores.net\/cdn\/shop\/files\/de-B0CJY473TS.jpg?v=1775749780","width":1122},{"alt":null,"id":34626781446297,"position":2,"preview_image":{"aspect_ratio":1.0,"height":1050,"width":1050,"src":"\/\/soundstores.net\/cdn\/shop\/files\/51Ov01FNAqL.jpg?v=1758722582"},"aspect_ratio":1.0,"height":1050,"media_type":"image","src":"\/\/soundstores.net\/cdn\/shop\/files\/51Ov01FNAqL.jpg?v=1758722582","width":1050},{"alt":null,"id":34626781479065,"position":3,"preview_image":{"aspect_ratio":1.0,"height":1050,"width":1050,"src":"\/\/soundstores.net\/cdn\/shop\/files\/51mrE86xYoL.jpg?v=1758722582"},"aspect_ratio":1.0,"height":1050,"media_type":"image","src":"\/\/soundstores.net\/cdn\/shop\/files\/51mrE86xYoL.jpg?v=1758722582","width":1050}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eHailege 2pcs 24V 5A AC Current Sensor Current Detection Relay 24V AC Current Relay Module AC Sensor Relay Switch with Overcurrent Protection\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eSpecifications: Operating voltage: DC 5 V \/ 12 V. 24 V. Working current: \u0026lt;20\nmA. Frequency range: 20 Hz - 400 Hz. Output mode: switching signal output.\nHumidity: 0-95% RH. Size: 4.4 x 3.8 cm \/ 1.73 x 1.5 inches. Interfaces: VCC:\nPositive; GND: Negative; NO: Normally open, NO and COM are disconnected before\nthe relay is closed, and short circuit after closing the relay COM: common,\ncommon relay interface; NC: Normally closed, NC and COM are short-circuited\nbefore the relay is closed, and disconnected after the relay is closed\nInstructions: 5A overcurrent protection. The sensor module uses a current\ntransformer to collect the AC signal to reach the overcurrent signal output of\nthe relay within 0-5 A. Relay cable in case of overcurrent, relay disengaged\nwhen there is no overcurrent. Users can use the three relay ports COM, NC, NO\nto turn the external circuit on and off to achieve overcurrent protection. Use\nthe potentiometer to adjust the overcurrent protection point, the right\nadjustment reduces the detection current. 1. Measure the wire through the\ncurrent transformer, connect VCC and GND to the DC12V power supply. 2. Adjust\nthe potentiometer when you hear the sound of the relay train (can be measured\nwith a multimeter COM and NO whether it was on when connected to the activated\nrelay mean), then reduce or interrupt the current flowing through the tested\ncable when the relay releases this overcurrent protection point at that time\n(available for COM and NC measurement of the multimeter. whether it is\nconnected when connected to the relay agent has been solved). Box contents: 2\nx AC current sensor relay modules (5V 12V 24V optional, you will receive the\ntwo same, no mixed types.)\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003eThe resolution of current detection can change the parameters of the resistance parameters\u003c\/li\u003e\n \u003cli\u003e5A AC current sensor current detection sensor\u003c\/li\u003e\n \u003cli\u003eAC relay switch, 5V 12V 24V optional\u003c\/li\u003e\n \u003cli\u003eAdjustment of the critical point of the overcurrent signal, adjustable, the current detection range AC0.3A-5A\u003c\/li\u003e\n \u003cli\u003eWe offer the declaration of conformity. This product also includes an electronic user manual available in English, German, French, Spanish, Italian, Polish and Dutch. If you need support, please contact us.\u003c\/li\u003e\n \u003c\/ul\u003e"}

Hailege 2pcs 24V 5A AC Current Sensor Current Detection Relay 24V AC Current Relay Module AC Sensor Relay Switch with Overcurrent Protection 24 V

In Stock. Leaves warehouse within 2 - 3 business days

$116.00 AUD
Maximum quantity available reached.
Free Shipping Australia Wide
100% Safe & Secure Checkout
100 Days Return Policy *
1 Year Warranty *

Hailege 2pcs 24V 5A AC Current Sensor Current Detection Relay 24V AC Current Relay Module AC Sensor Relay Switch with Overcurrent Protection

Specifications: Operating voltage: DC 5 V / 12 V. 24 V. Working current: <20 mA. Frequency range: 20 Hz - 400 Hz. Output mode: switching signal output. Humidity: 0-95% RH. Size: 4.4 x 3.8 cm / 1.73 x 1.5 inches. Interfaces: VCC: Positive; GND: Negative; NO: Normally open, NO and COM are disconnected before the relay is closed, and short circuit after closing the relay COM: common, common relay interface; NC: Normally closed, NC and COM are short-circuited before the relay is closed, and disconnected after the relay is closed Instructions: 5A overcurrent protection. The sensor module uses a current transformer to collect the AC signal to reach the overcurrent signal output of the relay within 0-5 A. Relay cable in case of overcurrent, relay disengaged when there is no overcurrent. Users can use the three relay ports COM, NC, NO to turn the external circuit on and off to achieve overcurrent protection. Use the potentiometer to adjust the overcurrent protection point, the right adjustment reduces the detection current. 1. Measure the wire through the current transformer, connect VCC and GND to the DC12V power supply. 2. Adjust the potentiometer when you hear the sound of the relay train (can be measured with a multimeter COM and NO whether it was on when connected to the activated relay mean), then reduce or interrupt the current flowing through the tested cable when the relay releases this overcurrent protection point at that time (available for COM and NC measurement of the multimeter. whether it is connected when connected to the relay agent has been solved). Box contents: 2 x AC current sensor relay modules (5V 12V 24V optional, you will receive the two same, no mixed types.)

Product Features

  • The resolution of current detection can change the parameters of the resistance parameters
  • 5A AC current sensor current detection sensor
  • AC relay switch, 5V 12V 24V optional
  • Adjustment of the critical point of the overcurrent signal, adjustable, the current detection range AC0.3A-5A
  • We offer the declaration of conformity. This product also includes an electronic user manual available in English, German, French, Spanish, Italian, Polish and Dutch. If you need support, please contact us.